Factory-Calibration

Dokumente einer Werkskalibrierung

Our calibration capabilities are not limited to the areas of accreditation. We strive to constantly expand our capabilities, including research and development of methods, procedures and fundamentals of gas physics.

The accredited quantities such as volume and mass flow or volume and mass of air and gases (as well as all others) are available for a broader measuring range in the form of a factory calibration. These areas have not yet been reviewed by a DAkkS auditor, but have already completed all TetraTec internal verifications. The non-accredited areas and procedures are generally strongly orientated towards the accredited processes and are in no way inferior to them in terms of quality. So if you develop a need for calibrations with very small gas flows, high pressures or using special pure or mixed gases, the solutions of our calibration laboratory are also available to you there.

Measured Variable
in the Laboratory
Measurement Range Calibration Standards Traceability
Volume Flow (Air) 0.06 mL/h to 10,000 m³/h Critical Nozzles, Gas meters, LFE, pVTt PTB
Mass Flow (Air) 0.072 mg/h to 12,000 kg/h Critical Nozzles, Gas Meters, LFE, pVTt PTB
Flow Generation (Air) up to 450 Nm³/h compressed air
(max. 8 bar abs)
up to 500/ 2000/ 10,000 m³/h
vacuum (-600/ -300/ -80 mbar)
Critical nozzles, Gas Meters, LFE PTB
Flow of Foreign Gas
N2, H2, He, O2, Ar, CO2,
CH4, CO, C3H8
2 µL/min to 1 mL/min Test Leak DAkkS / house procedure
N2, H2, He, O2, Ar, CO2,
CH4, CO, C3H8
0.65 mL/min to 400...600 L/min,
CH4 up to 150 L/min
CO and C3H8 up to 25 L/min
Gas meter, LFE DAkkS / house procedure
Absolute Pressure 14 mbar to 140 bar Piston manometer, electrical pressure sensors PTB
Positive Overpressure 0 to 140 bar Piston manometer, electrical pressure sensors PTB
Negative Overpressure -1 bar to 0 mbar Piston Manometer, electrical Pressure Sensors PTB
Temperature -40 to 130 °C Resistance thermometers, water bath DAkkS
Relative Humidity 10 to 95 % r.H. Dew Point Mirror, Electrical Humidity Sensor DAkkS
Direct Current Voltage 0 to 60 Volts System Multimeter DAkkS
Direct Current 0 to 3 Amperes System Multimeter DAkkS
Direct Current Resistance 0 to 12 MOhm Resistance Measuring Device, System
Multimeter, Fixed Resistor
DAkkS
Measured Variable
on Site
Measurement Range Calibration Standards Traceability
Volumetric Flow Rate (Air) 60 mL/h to 4,700 m³/h Gas Meter, LFE DAkkS
Mass Flow Rate (Air) 72 mg/h to 5,640 kg/h Gas Meter, LFE DAkkS
Flow Generation (Air) dependant on the customer's supply
Flow of Foreign Gas
N2, H2, He, O2, Ar, CO2, CH4
1 mL/min to 400...600 L/min,
CH4 up to 150 L/min
Medium supply by the customer
Gas Meter, LFE DAkkS / house procedure
Absolute Pressure 14 mbar to 140 bar Electronic Pressure Sensors DAkkS / house procedure
Positive Overpressure 0 to 140 bar Electronic Pressure Sensors DAkkS
Negative Overpressure -1 bar to 0 bar Electronic Pressure Sensors DAkkS
Temperature 5 to 90 °C Block, Water Bath DAkkS
Relative Humidity 11 to 75 % r.H. Electronic Humidity Sensor DAkkS
Direct Current Voltage 0 to 60 Volts System Multimeter DAkkS
Direct Current 0 to 3 Amperes System Multimeter DAkkS
Direct Current Resistance 0 to 12 MOhm Resistance Measuring Device, System
Multimeter, Fixed Resistor
DAkkS

For further information and quotations for the calibration, please contact us.